ALLIANCE AVIV: Safety and Effectiveness of the SAPIEN X4 Transcatheter Heart Valve in Failing Aortic Bioprosthetic Valves
Edwards Lifesciences · NCT05172973
Opens the official ClinicalTrials.gov record, with the study team’s contacts. Bored Studies doesn’t enroll anyone.
Key facts
- Compensation
- Not posted. Ask the study team before screening.
- Who can join
- Any age listed · All sexes
- Healthy volunteers
- Not accepted (a condition is required)
- Study type
- Interventional · Not applicable
- Target enrollment
- 200
- US sites recruiting
- 27
- Study start
- November 22, 2023
- Record last updated
- October 7, 2026
Status re-checked against ClinicalTrials.gov within the last 12 hours.
What the study is about
The objective of this study is to establish the safety and effectiveness of the Edwards SAPIEN X4/X4S Transcatheter Heart Valve (THV) in subjects who are at high or greater risk with a failing aortic bioprosthetic valve.
Being studied: SAPIEN X4/X4S THV
Conditions: Aortic Valve Insufficiency; Aortic Valve Stenosis
Eligibility criteria
Copied from the official record. The study team makes the final decision at screening.
Show full criteria
Inclusion Criteria
- Failing aortic bioprosthetic valve demonstrating ≥ moderate stenosis and/or ≥ moderate insufficiency
- Bioprosthetic valve size suitable for SAPIEN X4 THV
- NYHA functional class ≥ II
- Heart Team agrees the subject is at high or greater surgical risk
- The subject has been informed of the nature of the study, agrees to its provisions and has provided written informed consent.
Exclusion Criteria
- Anatomical characteristics that would preclude safe femoral placement of the introducer sheath or safe passage of the delivery system
- Failing valve has moderate or severe paravalvular regurgitation
- Failing valve is unstable, rocking, or not structurally intact
- Known severe patient-prosthesis mismatch or bioprosthetic valve with residual mean gradient > 20 mmHg at the end of the index procedure for implantation of the original valve
- Increased risk of THV embolization
- Surgical or transcatheter valve in the mitral position
- Severe mitral regurgitation (> 3+) or ≥ moderate mitral stenosis
- Need for mitral, tricuspid or pulmonic valve intervention within the next 12 months
- Left ventricular ejection fraction \< 20%
- Cardiac imaging evidence of intracardiac mass, thrombus or vegetation
- Increased risk of coronary artery obstruction after THV implantation
- Myocardial infarction within 30 days prior to the study procedure
- Hypertrophic cardiomyopathy with subvalvular obstruction
- Subjects with planned concomitant ablation for atrial fibrillation
- Clinically significant coronary artery disease requiring revascularization
- Any surgical or transcatheter procedure within 30 days prior to the study procedure. Implantation of a permanent pacemaker or implantable cardioverter defibrillator is not considered an exclusion.
- Any planned surgical or transcatheter intervention to be performed within 30 days following the study procedure
- Endocarditis within 180 days prior to the study procedure
- Stroke, transient ischemic attack or neurological signs and symptoms attributed to carotid or vertebrobasilar disease within 90 days prior to the study procedure
- Hemodynamic or respiratory instability requiring inotropic or mechanical support within 30 days prior to the study procedure
- Renal insufficiency and/or renal replacement therapy
- Leukopenia, anemia, thrombocytopenia
- Inability to tolerate or condition precluding treatment with antithrombotic therapy
- Hypercoagulable state or other condition that increases risk of thrombosis
- Absolute contraindications or allergy to iodinated contrast that cannot be adequately treated with premedication
- Subject refuses blood products
- Body mass index > 50 kg/m2
- Estimated life expectancy \< 24 months
- Female who is pregnant or lactating
- Active SARS-CoV-2 infection or previously diagnosed with COVID-19 with sequelae that could confound endpoint assessments
- Participating in another investigational drug or device study that has not reached its primary endpoint
- Subject considered to be part of a vulnerable population
Recruiting US locations
Bay Area Structural Heart at Sutter Health
San Francisco, CA 94105
Stanford University Medical Center
Stanford, CA 94305
UC Health Medical Center of the Rockies
Loveland, CO 80538
Naples Community Hospital Healthcare System
Naples, FL 34102
Emory University Atlanta
Atlanta, GA 30308
Piedmont Heart Institute
Atlanta, GA 30309
Northwestern University Chicago
Evanston, IL 60208
Alexian Brothers Hospital Network
Lisle, IL 60532
Ascension Via Christi St. Francis (Cardiovascular Research Institute of Kansas)
Wichita, KS 67226
MedStar Union Memorial Hospital
Baltimore, MD 21218
Henry Ford Hospital Detroit
Detroit, MI 48202
Mayo Clinic
Rochester, MN 55905
Atlantic Health System Morristown
Morristown, NJ 07960
Robert Wood Johnson University Hospital
New Brunswick, NJ 08901
University of Buffalo
Buffalo, NY 14203
Cornelll University New York
New York, NY 10021
Columbia University Medical Center / NYPH
New York, NY 10032
Montefiore Medical Center
New York, NY 10458
Rochester General Hospital
Rochester, NY 14621
Novant Health and Vascular Institute
Charlotte, NC 28204
The Christ Hospital
Cincinnati, OH 45219
The Cleveland Clinic Foundation
Cleveland, OH 44195
Oklahoma Heart Institute
Tulsa, OK 74104
Kaiser Portland
Clackamas, OR 97015
Allegheny General Hospital
Pittsburgh, PA 15212
Saint Thomas Health
Nashville, TN 37205
The Heart Hospital Baylor Plano
Plano, TX 75093
Study contacts (from the official record)
- Edwards THV Clinical Affairs · 949-250-2500 · THV_CT.gov@Edwards.com