Safety and Efficacy of Endovascular Treatment of Intracranial Aneurysms With Surpass Elite With GUARDian Flow Diverter (GUARD)
Stryker Neurovascular · NCT06872684
Opens the official ClinicalTrials.gov record, with the study team’s contacts. Bored Studies doesn’t enroll anyone.
Key facts
- Compensation
- Not posted. Ask the study team before screening.
- Who can join
- Ages 18–80 · All sexes
- Healthy volunteers
- Not accepted (a condition is required)
- Study type
- Interventional · Not applicable
- Target enrollment
- 183
- US sites recruiting
- 20
- Study start
- June 20, 2025
- Record last updated
- October 21, 2026
Status re-checked against ClinicalTrials.gov within the last 12 hours.
What the study is about
The objective of the Safety and Efficacy of Endovascular Treatment of Intracranial Aneurysms with Surpass Elite with GUARDian Flow Diverter (GUARD) trial is to evaluate the safety and efficacy of the Surpass Elite with Guardian Flow Diverter System (FDS) in the treatment of unruptured, wide-neck saccular or fusiform, intracranial aneurysms (IAs) located on the internal carotid artery (ICA) or its branches.
Being studied: Surpass Elite with Guardian Flow Diverter System
Conditions: Aneurysm; Aneurysm, Intracranial
Eligibility criteria
Copied from the official record. The study team makes the final decision at screening.
Show full criteria
Inclusion Criteria
- Age is ≥18 and ≤80 years at the time of consent
- Has a single unruptured target intracranial aneurysm (IA) of any size with the following characteristics:
- Is located on the internal carotid artery or its branches
- Has a wide neck (wide neck typically defined as neck width ≥ 4 millimeter (mm), or dome to neck ratio ≤ 2.0) or no discernible neck
- Aneurysm is either saccular or fusiform in nature
- Has a parent vessel diameter ≥ 3.0 mm to ≤ 6.0 mm at the largest diameter
- There is documented risk-benefit of endovascular treatment that outweighs the risks of intracranial aneurysm rupture during the subject's expected lifetime if left untreated.
Exclusion Criteria
- Has an extradural target aneurysm
- Has a target aneurysm in the posterior circulation
- Perforator or branch vessel, inclusive of the posterior communicating artery, arises from the target aneurysm body or neck (branches or arteries must arise or connect from the parent vessel separate from the aneurysm or neck to not be excluded from trial)
- Has a true bifurcation aneurysm, defined as an aneurysm (saccular or non-saccular) located at a point of vessel bifurcation
- Has vessel characteristics, such as severe tortuosity (cavernous Internal Carotid Artery (cICA) Type IV1), stenosis (>70%), or morphology that would preclude safe endovascular access or proper deployment of the trial device to the target aneurysm
- Received previous treatment for the target aneurysm or parent artery where it would interfere with the placement or proper apposition of the device
- Has a medical contraindication to trial or procedure related antiplatelet medications (aspirin, clopidogrel/Plavix, ticagrelor, and heparin), local or general anesthesia, or life-threatening allergy to contrast dye
- Has a known severe allergy to nickel, chromium cobalt, tungsten, or platinum
- Patients with heparin hypersensitivity, including patients with a previous incident of Heparin-Induced Thrombocytopenia (HIT).
- Modified Rankin Score (mRS) assessment is ≥ 3 at pre-procedure exam
- Presence of unstable neurological deficit (i.e., worsening of clinical condition in the last 30 days prior to the index procedure)
- Subarachnoid hemorrhage occurred within 30 days prior to the index procedure
- Major surgery (including previous intracranial implant) either occurred within 30 days prior to the index procedure date or is planned to occur within 120 days following the index procedure date
- Has more than one intracranial aneurysm (IA) that requires treatment within 12 months after the index procedure
- Received previous intracranial implant associated with the symptomatic or vascular distribution within the past 84 days prior to treatment date
- Chronic anticoagulation therapy is ongoing or known coagulopathy exists
- Has atrial fibrillation with or without pacemaker.
- Has other known serious concurrent medical conditions such as cardiovascular disease (including recent myocardial infarction [\<12 weeks], symptomatic congestive heart failure, or carotid stenosis), kidney failure (>2.0 mg/dl serum creatinine), pulmonary disease, uncontrolled diabetes, progressive neurologic disorders, terminal cancer, vasculitis, high risk of ischemic stroke or recent stroke
- Has acute life-threatening illness (e.g., acute kidney or heart failure) other than the neurological disease to be treated in this trial
- Evidence of active infection at the time of treatment
- Life expectancy is less than 5 years due to other illness or condition (in addition to an intracranial aneurysm)
- Unable to comply with the trial follow up requirements due to conditions such as dementia or psychiatric problems, active substance abuse, or history of non-compliance with medical advice, as determined by the investigator
- Pregnant or breast- feeding women or women who wish to become pregnant during the length of trial participation
- Presence of intracranial mass (tumor, except meningioma, abscess, or other infection), non-treated arteriovenous malformation (AVM) in the territory of the target aneurysm
- Enrollment in another study involving an investigational product that could confound the outcomes of this trial
Recruiting US locations
Carondelet St. Joseph's Hospital
Tucson, AZ 85711
Site contact: Rachael Taoka · 520-873-1592 · Rachael2.taoka@tenethealth.com
University of California Davis Health
Davis, CA 95616
Site contact: Savina Nguyen · 916-551-3234 · savnguyen@ucdavis.edu
University of California Los Angeles (UCLA)
Los Angeles, CA 90095
Site contact: Victoria Rueda · 310-562-9694 · vrueda@mednet.ucla.edu
Stanford University School of Medicine
Palo Alto, CA 94304
Site contact: Banu Priya Rajasekaran · 650-304-6402 · bpriya@stanford.edu
Lyerly Neurosurgery, an Affiliate of Baptist
Jacksonville, FL 32207
Site contact: Karen Yesensky · 904-202-7091 · karen.yesensky@bmcjax.com
Baptist Hospital of Miami
Miami, FL 33176
Site contact: Marianela Cruz · 786-596-5175 · marianela.cruz@baptisthealth.net
Indiana University
Indianapolis, IN 46202
Site contact: Lauren Snyder · 317-968-8172 · lmillar@iu.edu
University of Iowa Healthcare
Iowa City, IA 52242
Site contact: Heena Olalde · 319-356-8326 · heena-olalde@uiowa.edu
University of Kansas Medical Center
Kansas City, KS 66160
Site contact: Max Hardenbrook · 913-588-6191 · mhardenbrook@kumc.edu
Lahey Hospital and Medical Center
Burlington, MA 01803
Site contact: Sandy Alvarez · 786-580-0186 · Sandy.L.Alvarez@lahey.org
Robert Wood Johnson University Medical Center
New Brunswick, NJ 08901
Site contact: Christine Yohn · 908-328-4210 · cy253@rwjms.rutgers.edu
Mount Sinai Health System
New York, NY 10029
Site contact: Emily Svendsen · 212-241-3238 · emily.svendsen@mountsinai.org
University of Rochester Medical Center
Rochester, NY 14618
Site contact: Tilor Hallquist · 585-261-8969 · tilor_hallquist@urmc.rochester.edu
Stony Brook University Hospital
Stony Brook, NY 11794
Site contact: Marlene Baumeister · 631-444-1610 · marlene.baumeister@stonybrookmedicine.edu
Montefiore Medical Center
The Bronx, NY 10467
Site contact: Lyanna Gomez · 718-920-2512 · lygomez@montefiore.org
Cleveland Clinic
Cleveland, OH 44195
Site contact: Barmen Joyce · 216 445-5869 · BARMENJ2@ccf.org
Oregon Health & Science University
Portland, OR 97239
Site contact: Emilie Nagle · 503-418-1722 · bode@ohsu.edu
University of Pennsylvania
Philadelphia, PA 19104
Site contact: Leah Coghlan · 215-341-5864 · Leah.coghlan@pennmedicine.upenn.edu
Semmes Murphey
Memphis, TN 38120
Site contact: Wendell Barnett · 901-260-6124 · wbarnett@semmes-murphey.com
The University of Texas Medical Branch at Galveston
Galveston, TX 77555
Site contact: Elizabeth Hennessey · 409-772-2138 · eahennes@utmb.edu
Study contacts (from the official record)
- Stacy Phung · 678-469-2428 · stacy.phung@stryker.com
- John Strohmeyer · john.strohmeyer@stryker.com